LESSON 4: ELECTRICAL CONTROL SYSTEMS (NON-ECM)

4.4 Comparison - Open/Closed Electrical Controls
INDEX
page 4 of 5 < PREVIOUS | NEXT >



  • Electrical switches are wired in parallel.

  • Air supply plumbed to solenoid's normally-open port (the end port).

  • Test fan drive by installing a jumper wire across a sensor.

  • Manual override switch (if equipped).
  • Electrical switches are wired in series.

  • Air supply plumbed to solenoid's normally-closed port (the side port).

  • Test fan drive by disconnecting a wire from a sensor.

  • Manual override switch (if equipped).

Learning Objectives:
• For each type of control system determine: 1) if switches are wired in parallel or series, 2) if sensors are used, 3) the proper port to plumb the solenoid valve, and 4) the proper method to test the fan drive.