LESSON 7: DISASSEMBLING THE FAN DRIVE

7.2 Disassembly
INDEX
page 4 of 6 < PREVIOUS | NEXT >
video clip with audio narrated
Air Chamber Seals


11. Remove the air chamber cap retaining ring.

12. Gently and evenly pry the air chamber cap out of the sheave using two small screwdrivers placed 180° apart.

13. Remove the O-ring seal from the air chamber cap.

14. Remove the face seal.

15. Inspect the face seal for signs of wear. Wear indicates that dirt may exist in the air system.


Learning Objectives:
• Describe the steps of removing and inspecting the air chamber seals.

WARNING
Wear eye safety protection when removing retaining ring to avoid serious injury.

CAUTION
If dirt or oil exists in the air system, the air system must be cleaned and dried before the fan drive is reinstalled.

NOTE:
If you are only installing a Seal Kit, proceed to 8.2, step 20.